HVAC Damper Supplier · 6 damper types · Factory Direct
HVAC dampers,wholesale from factory.
Volume dampers, backdraft dampers, motorized dampers, OBD/MS integrated dampers, and return air dampers — manufactured in Dongyang, China. In-house actuator assembly. MOQ from 100 pcs.
Six HVAC damper categories
Multi-blade opposed-action volume control dampers integrated into ceiling diffusers and registers. Aluminum blades with steel frame. Used for zone-level airflow balancing in VAV and constant-volume systems.
Integrated in diffuserSteel multi-shutter dampers factory-installed in sidewall registers and ceiling diffusers. Quick-open/close airflow control with locking position. Adjustable from inside the face grille without tools.
Integrated in registerGravity-operated aluminum backdraft dampers for exhaust and supply air applications. Prevents reverse airflow when fan shuts off. Available as standalone units or frame-integrated with grilles. Sizes 6"–24".
From $4/pc FOBRound and rectangular volume control dampers for duct branch balancing. Single blade (SBD) and opposed blade (OBD) configurations. Galvanized steel construction. Manual quadrant or locking handle.
From $6/pc FOBElectrically actuated dampers with 24V AC/DC or 230V spring-return actuators. Normally open or normally closed. Used in VAV boxes, zone control, and fresh air systems. BACnet/Modbus available on request.
From $18/pc FOBReturn air dampers integrated into return air grilles and filter grilles. Hinged or sliding access panels. Removable-core designs for easy filter changes. Used in plenum return HVAC systems.
Integrated in grilleHVAC damper specifications at a glance
Compare damper type, size range, material, drive and MOQ before you request pricing. Leakage class is not published here — ask at RFQ whether a leakage test report is available for the exact model. For type-by-type selection, see our HVAC damper types guide.
| Type | Size | Material | Drive | Leakage class | MOQ | Catalog models |
|---|---|---|---|---|---|---|
| Opposed blade (OBD) | Matches host diffuser / register neck; rectangular duct-mount to order | Steel or aluminum | Manual — adjusted through the face; actuator-ready on request | Confirm at RFQ | 100 pcs | AD, 92OOV, SR7, AR7 |
| Multi-shutter (MS) | Factory-fitted in register sizes | Steel | Manual — lever behind the face grille | Confirm at RFQ | 100 pcs (host register MOQ) | 310 Series, CM3, 664 |
| Volume control (VCD) / butterfly | Round 4"–24" (butterfly); rectangular to duct size; diffuser-mount round dampers matched to neck | Galvanized steel; diffuser-mount models by model | Manual quadrant or locking handle | Confirm at RFQ | 100 pcs | 12, 22, 3800, T19 |
| Backdraft (gravity) | 6"–24" | Aluminum | Gravity — no power | Confirm at RFQ | 100 pcs | Quoted to spec |
| Motorized | Round and rectangular, by model | Galvanized steel, aluminum or stainless frame (to order) | 24V AC/DC or 230V spring-return; NO or NC | Confirm at RFQ | 50 pcs | Quoted to spec |
| Return air (in grille) | Matches return / filter grille size | Aluminum or steel (by grille) | Manual | Confirm at RFQ | 100 pcs (host grille MOQ) | RED5 |
Last updated: 2026-11-10. Standalone OBD and butterfly dampers are listed under HVAC accessories & plenums; register and diffuser dampers are listed with their host models.
How to buy HVAC dampers in bulk
Order terms for distributors, mechanical contractors and OEM buyers sourcing dampers by the carton or container.
MOQ
Backdraft and standalone volume control dampers: 100 pcs per model. Motorized dampers: 50 pcs per model. OBD / MS dampers built into diffusers and registers follow the host product MOQ (100 pcs).
Samples
Sample orders of 1–5 pcs per model. Standard items ship within 3–5 business days; samples for custom specs take 5–7 days. Sample cost is deducted from the first production order.
Lead time
Standard catalog dampers: 25–35 days after order confirmation. Custom sizes, special materials and motorized assemblies are confirmed with your quote.
Mixed orders
Mix damper types and sizes in one container order. Most buyers add ceiling diffusers, registers and plenum boxes to the same shipment — one PO, one FOB quote.
Packaging
Standard export cartons, or custom packaging, barcodes and spec sheets under your brand for distributor and private-label orders.
Documents
UL 181 listing for our flexible ducts is in progress. Ask for test reports and applicable documents for the exact model before you specify it for a project.
What to include in your damper RFQ
- Damper type and quantity per size (round diameter or rectangular W × H)
- Frame and blade material — galvanized steel, aluminum or stainless
- Drive: manual quadrant / locking handle, gravity, or motorized
- Motorized only: voltage (24V AC/DC or 230V), control signal (on/off, 0–10V or floating), spring return, normally open or normally closed, and actuator brand if you need Belimo, Honeywell, Siemens or Distech
- Backdraft only: airflow direction and mounting position (wall, duct or fan outlet)
- Leakage or test documents your project requires
- Drawings or a reference photo for non-standard sizes
- Destination port and whether you want dampers combined with grilles, diffusers or plenums
Specs to confirm by damper type
Motorized dampers: match actuator torque to damper area and static pressure, and decide fail position (spring-return open or closed) before ordering. Our motorized damper vs manual damper guide has round sizing and actuator tables.
Backdraft dampers: confirm airflow direction, gravity vs spring-assisted blades, and where the damper mounts. See the backdraft damper guide.
Fire and smoke dampers: local codes usually require a listed product. Our dampers are not UL listed, so we quote fire-rated assemblies only as custom builds with model-specific test reports. Read the fire damper and smoke damper guide before you specify.
Why source HVAC dampers from Airwise
Integrated + standalone
Source OBD/MS dampers integrated in diffusers and registers, or as standalone duct components — all from one manufacturer. One PO, one quality standard.
Product documents on request
UL 181 listing for our flexible ducts is in progress. Ask for test reports and applicable documents for the exact damper model.
In-house actuator assembly
Motorized dampers assembled in-house with our own actuators or OEM Belimo/Honeywell on request. Factory-tested before shipment. BACnet integration available.
Custom configurations
Non-standard blade counts, custom frame materials (galvanized, aluminum, stainless), acoustic lining, and fire-rated assemblies. Engineering support included.
Dampers + diffusers + plenums — one supplier
Most of our damper customers also source grilles, diffusers, and plenum boxes from us. One container, one quality standard, one FOB quote.
Ceiling Diffusers
16 models. Round, square 4-way, louvered, modular core. With OBD or MS damper options.
Return Air Grilles
17 types. Fixed-blade, removable-core, egg crate. Surface and flush mount.
Plenum Boxes
72+ SKUs. Supply and return air plenums. R-4.2 and R-6 insulation. Custom fabrication.
All HVAC Parts
234+ products across 12 categories. Full container load sourcing from one manufacturer.
HVAC damper wholesale — frequently asked questions
What types of HVAC dampers do you manufacture?▾
We manufacture: (1) Opposed Blade Dampers (OBD) integrated in ceiling diffusers; (2) Multi-Shutter Dampers (MS) in registers; (3) Backdraft dampers for exhaust applications; (4) Standalone volume control dampers; (5) Motorized dampers with 24V or 230V actuators. We also supply dampers as separate components to distributors who source diffusers and registers from us.
Are your dampers UL certified?▾
No. Our dampers and integrated diffuser and register assemblies are not UL listed. Request product-specific test reports before specifying a model for a project.
Can you match Belimo or Honeywell actuator interfaces for motorized dampers?▾
Yes. We manufacture damper bodies that accept Belimo, Honeywell, Siemens, and Distech actuators, and can also supply complete assemblies with these OEM actuators on request. We also manufacture our own 24V AC/DC spring-return actuators with 0–10V or floating point control. Send your control system specifications and we will confirm compatibility.
What is the MOQ for HVAC damper orders?▾
Backdraft dampers and standalone VCDs: 100 pcs per model. Motorized dampers: 50 pcs per model (higher unit value). OBD/MS dampers integrated with diffusers and registers follow the same MOQ as the host product (100 pcs). Mix of damper sizes within a single container order is accepted.
What is the lead time and sample policy for bulk damper orders?▾
Standard catalog dampers ship 25–35 days after order confirmation. Samples of 1–5 pcs per model are available: standard items ship within 3–5 business days, custom-spec samples take 5–7 days, and sample cost is deducted from your first production order. Lead time for custom sizes and motorized assemblies is confirmed with the quote.
What is the typical wholesale price for HVAC dampers from China?▾
Gravity backdraft dampers: $4–12/pc FOB depending on size. Round volume control dampers: $6–18/pc. Motorized dampers with actuator: $18–45/pc. Rectangular opposed-blade dampers: $8–22/pc. These are reference FOB China prices for standard stocking orders of 200+ pcs. Request a quote for your specific requirements.
Do you sell dampers as standalone components separate from diffusers?▾
Yes. While many customers source our dampers integrated with ceiling diffusers and registers, we also supply OBD, VCD, and backdraft dampers as standalone duct components. This is common for mechanical contractors who need replacement dampers or are sourcing duct dampers for a project separate from the grille supply.
Source HVAC dampers factory direct
Send your damper specifications or parts list and receive a FOB quote within 12 hours.